WESgraphwind farm domain knowledge graph
Model

CP from axial induction factor

The relationship between the power coefficient C_P and the axial induction factor a according to one-dimensional momentum theory: C_P = 4a(1-a)². Note that not all roots are physical when solving for a.

Open in the explorer → Suggest an edit

Includes 2

References

Contributed by

E.R.G. Quaeghebeur (TU Delft)

Cite the database: Quaeghebeur, E., Sanchez Perez-Moreno, S., and Zaaijer, M. B.: WESgraph: a graph database for the wind farm domain, Wind Energ. Sci., 5, 259–284, 2020. doi:10.5194/wes-5-259-2020