WESgraphwind farm domain knowledge graph
ModelElectricityMBZ13

geometrical factor for cable insulation thermal resistance

A model for the geometrical factor of the thermal resistance between conductor and sheath, fitted to a graph of Anders: G = −0.36⋅(t_i/D_c)^4 + 1.9⋅(t_i/D_c)^3 − 3.7⋅(t_i/D_c)^2 + 3.8⋅(t_i/D_c) + 0.24.

Open in the explorer → Suggest an edit

Includes 2

Notes

References

Contributed by

S. Sanchez Perez Moreno (TU Delft), Edited by S. Sanchez Perez-Moreno (Anemona)

Cite the database: Quaeghebeur, E., Sanchez Perez-Moreno, S., and Zaaijer, M. B.: WESgraph: a graph database for the wind farm domain, Wind Energ. Sci., 5, 259–284, 2020. doi:10.5194/wes-5-259-2020